• Back

  • E-Stop & Guard Monitoring Safety Relays

    ES Series and GM Series

    Safety Relay Module
    • Modules monitor up to 10 external devices for contact failure or wiring faults
    • Module goes into lockout mode if it detects a fault
    • Available voltages include 24V dc 24V ac/dc 115V ac or 12 to 24V dc or 230V ac or 12 to 24V ac/dc
    • Modules monitor positive-opening E-stop and interlock switches
    • Models are available with 2 to 4 normally open safety outputs, depending on module
    • Safety outputs are rated 4 or 6 amps, depending on module
    • Non-safety auxiliary outputs are available on most modules
    • Two modules allow central monitoring and control over a DeviceNet control network
    • Ratings are NEMA 1 and at least IEC IP20
    • Housings are rugged polycarbonate
    • Bright red and green LED indicators show modules operating status

    Technical Literature

    Date
    Type
    Size
    GM-FA-10J Gate Monitoring Module (24 VAC/VDC, Single or Dual Inputs)
    12 Jul 2023
    Datasheet
    1.1MB
    ES-FA-9AA and ES-FA-11AA Safety Modules (Short Multi-Lingual)
    20 Jan 2022
    Datasheet
    92K
    ES-UA/VA-5A Safety Modules (4 N.O. safety outputs, 12-24 V DC/115  or 230 V AC)
    11 Aug 2021
    Datasheet
    466K
    ES-FA-6G Safety Module (3 N.O. safety outputs, 24V ac/dc, 1 input)
    12 Jul 2019
    Datasheet
    296K
    ES-TA-3F1 Safety Module (2 N.O. safety outputs, 24V dc, 10 inputs, DeviceNet)
    18 Aug 2006
    Datasheet
    651K
    ES-FA-9A Safety Module (3 N.O. safety outputs, 24V ac/dc, 1 or 2 inputs)
    15 Mar 2004
    Datasheet
    126K
    ES-TA-3D1 Safety Module (2 N.O. safety outputs, 24V dc, 6 inputs, DeviceNet)
    10 Nov 2003
    Datasheet
    456K
    Date
    Type
    Size
    Date
    Type
    Size
    ES-UA/VA-5A Safety Modules (4 N.O. safety outputs, 12-24 V DC/115  or 230 V AC) (German)
    09/01/22
    Datasheet
    470K
    Date
    Type
    Size
    Date
    Type
    Size
    ES-TN-1Hx Safety Modules (4 N.O. safety outputs, fixed delay)  - Japanese
    04/28/11
    Datasheet
    683K
    ES-UA-5A/ES-VA-5A Safey Modules - Japanese
    04/28/11
    Datasheet
    613K
    ES-TN-1H5/6 Safety Modules (4 N.O. safety ouptus, 24V dc, adj delay) - Japanese
    04/28/11
    Datasheet
    728K
    ES-FA-6G Safety Module (3 N.O. safety outputs, 24Vac/dc, 1 input) - Japanese
    04/28/11
    Datasheet
    298K
    ES-FA-9AA Safety Module (3 N.O safety outputs,24Vac/dc,1 or 2 inputs) - Japanese
    04/28/11
    Datasheet
    475K
    ES-GA-5A/ES-HA-5A Safety Modules - Japanese
    04/28/11
    Datasheet
    285K
    ES-TN-14H5/6 Safety Modules (8 N.O safety outputs, 24Vdc, adj delay) - Japanese
    04/28/11
    Datasheet
    590K
    Date
    Type
    Size
    ES-FA-9AA and ES-FA-11AA Safety Modules (Spanish)
    05/17/24
    Product Manual
    2.6MB

    Software

    Date
    Type
    Size
    ES-TA-3F1
    ES-TA-3F1
    13 Jan 2003
    Software
    3K
    ES-TA-3D1
    ES-TA-3D1
    13 Jan 2003
    Software
    3K
    Icon 131, bmp format
    13 Jan 2003
    Software
    1K
    Icon 131, ico format
    13 Jan 2003
    Software
    1K

    Marketing Literature

    Date
    Type
    Size
    Safety Solutions Catalog
    Safety Solutions Catalog
    13 May 2024
    Product Brochure
    11.5MB
    Safety Overview Flyer
    Safety Overview Flyer
    15 Feb 2023
    Product Brochure
    2.5MB
    (Part D) 2006-07 Safety Catalog (Pg 105-134) - Safety Modules
    4 Apr 2006
    Catalog
    1.9MB
    Date
    Type
    Size
    CN_Safety Solutions Catalog
    安全解决方案
    06/09/23
    Product Brochure
    14.8MB
    Date
    Type
    Size
    Machine Safety Catalog (09) - Emergency Stop Safety Modules - Japanese
    11/18/02
    Catalog
    814K
    Date
    Type
    Size
    F142 Safety Solutions Brochure
    01/06/21
    Product Brochure
    16.4MB
    Gate Monitoring Module
    Gate Monitoring Module

    The safety module monitors the magnetic sensor for actuation when the guard opens, for failure modes, and for closing. It also provides two safe switching outputs and monitoring of device under control.

    Read More

    Product Selection

    Loading...

    Narrow Results

    clear all filters

    Number of Safe Inputs

    • (5)
    • (1)

    Output Configuration

    • (2)
    • (2)
    • (2)

    Supply Voltage

    • (3)
    • (1)
    • (1)
    • (1)

    Gate Switch (NC/NC) Input

    • (2)
    • (4)

    Gate Switch (NC/NO) Input

    • (5)
    • (1)

    Safety Module Type

    • (5)
    • (1)
    View All View Less
    selected filters
    1. ES-FA-9AA

      logo with r symbol

      Safety Relay Module for E-Stop/Rope Pull/Interlock
      Supply Voltage: 24 V ac/dc
      Safety Input: 1 Dual/Single Channel
      Safety Output: 3 NO, 6 A; Aux Output: None
      Terminal Block: Removable; Width: 22.5 mm
      Self-Checking Circuitry, Auto/Manual Reset

    2. ES-UA-5A

      logo with r symbol

      Safety Relay Module for E-Stop/Rope Pull/Interlock
      Supply Voltage: 115 V ac or 12-24 V dc
      Safety Input: 1 Dual/Single Channel
      Safety Output: 4 NO, 6 A; Aux Output: 1 NC, 5 A and 2 Solid-State 0.1 A
      Terminal Block: Removable; Width: 45 mm
      Self-Checking Circuitry, Auto/Manual Reset

    3. ES-FA-11AA

      logo with r symbol

      Safety Relay Module for E-Stop/Rope Pull/Interlock
      Supply Voltage: 24 V ac/dc
      Safety Input: 1 Dual/Single Channel
      Safety Output: 2 NO, 7 A; Aux Output: 1 NC, 7 A
      Terminal Block: Removable; Width: 22.5 mm
      Self-Checking Circuitry, Auto/Manual Reset

    4. GM-FA-10J

      logo with r symbol

      Safety Relay Module for Interlocks
      Supply Voltage: 24 V ac/dc
      Safety Input: Interlocks with complementary contacts
      Safety Output: 2 NO, 6 A; Aux Output: None
      Terminal Block: Removable; Width: 22.5 mm
      Self-Checking Circuitry, Auto/Manual Reset

    5. ES-FA-6G

      logo with r symbol

      Safety Relay Module for E-Stop/Rope Pull/Interlock
      Supply Voltage: 24 V ac/dc
      Safety Input: 1 Single Channel
      Safety Output: 3 NO, 6 A; Aux Output: 1 NC, 6 A
      Terminal Block: Fixed; Width: 22.5 mm
      Self-Checking Circuitry, Auto/Manual Reset

    6. ES-VA-5A

      logo with r symbol

      Safety Relay Module for E-Stop/Rope Pull/Interlock
      Supply Voltage: 230 V ac or 12-24 V dc
      Safety Input: 1 Dual/Single Channel
      Safety Output: 4 NO, 6 A; Aux Output: 1 NC, 5 A and 2 Solid-State 0.1 A
      Terminal Block: Removable; Width: 45 mm
      Self-Checking Circuitry, Auto/Manual Reset

    Add to My Library
    Added