Safety Grid System

SGS Series

SGS Safety Grid Systems are cost-effective multiple beam safety light devices for access and long-range perimeter guarding applications. They are available in Emitter/Receiver models capable of safeguarding over very long distances and in easy-to-deploy Active/Passive models that offer additional cost savings.

  • Models available with integral muting for entry/exit conveyors or palletizing cells
  • Heavy-duty aluminum housing for tough environments
  • Easy alignment and installation with on-board alignment lamp and indicators
  • Protective defined area heights of 500, 800, 900, or 1200 mm available
  • Up to 60 meter range available for perimeter guarding applications
  • Muting arm kits available to simplify end-of-line packaging applications
OPTIMIZE CONTROL SYSTEM PERFORMANCE
Remote I/O

Technical Literature

Date
Type
Size
SGS Safety Grid System (Emitter-Receiver Models) Instruction Manual
5 Oct 2023
Product Manual
7.7MB
SGS Safety Grid System (Active-Passive Models) Instruction Manual
5 Oct 2023
Product Manual
8.1MB
SGS Safety Grid System (Emitter-Receiver Models with Integral Muting) Instruction Manual
5 Oct 2023
Product Manual
7.5MB
SGS Safety Grid System (Active-Passive Models with Integral Muting) Instruction Manual
5 Oct 2023
Product Manual
7.9MB
SGSA-LXT Muting Arm Sensor Kits for SGS Safety Grid Systems with Integral Muting
2 Aug 2021
Datasheet
633K
SGS Safety Grid System Semi-Annual Checkout Procedure (Muting Models)
16 Jan 2018
Checkout Procedure
92K
SGS Safety Grid System Daily Checkout Procedure (Muting Models)
16 Jan 2018
Checkout Procedure
121K
SGS Safety Grid System Daily Checkout Procedure (Non-Muting Models)
16 Jan 2018
Checkout Procedure
121K
SGS Safety Grid System Semi-Annual Checkout Procedure (Non-Muting Models)
16 Jan 2018
Checkout Procedure
88K
SGSA-MCB Safety Grid System Connection Box
22 Sep 2017
Datasheet
460K
Date
Type
Size
SGS Safety Grid System (Emitter/Receiver with Integral Muting) -- Instruction Manual (French)
12/19/19
Product Manual
13.6MB
SGS Safety Grid System (Emitter/Receiver) -- Instruction Manual (French)
12/19/19
Product Manual
4.6MB
SGS Safety Grid System (Active/Passive with Integral Muting) - Instruction Manual (French)
12/19/19
Product Manual
14.5MB
SGS Safety Grid System (ActivePassive) -- Instruction Manual (French)
12/19/19
Product Manual
5.4MB
SGS Safety Grid System Semi-Annual Checkout Procedure (Non-Muting Models) (French)
01/04/19
Checkout Procedure
82K
SGS Safety Grid System Daily Checkout Procedure (Non-Muting Models) (French)
01/04/19
Checkout Procedure
115K
SGSA-LXT Muting Arm Sensor Kits for SGS Safety Grid Systems with Integral Muting (French)
08/06/18
Datasheet
583K
SGS Safety Grid System Daily Checkout Procedure (Muting Models) (French)
08/06/18
Checkout Procedure
115K
SGS Safety Grid System Semi-Annual Checkout Procedure (Muting Models) (French)
08/06/18
Checkout Procedure
86K
Date
Type
Size
SGS Safety Grid System (Emitter/Receiver with Integral Muting) -- Instruction Manual (German)
02/14/20
Product Manual
13.3MB
SGS Safety Grid System (Active/Passive with Integral Muting) - Instruction Manual (German)
02/14/20
Product Manual
14.5MB
SGS Safety Grid System (ActivePassive) -- Instruction Manual (German)
02/14/20
Product Manual
5.4MB
SGS Safety Grid System (EmitterReceiver) -- Instruction Manual (German)
02/14/20
Product Manual
4.6MB
SGS Safety Grid System Daily Checkout Procedure (Non-Muting Models) (German)
01/04/19
Checkout Procedure
108K
SGS Safety Grid System Semi-Annual Checkout Procedure (Non-Muting Models) (German)
01/04/19
Checkout Procedure
75K
SGSA-LXT Muting Arm Sensor Kits for SGS Safety Grid Systems with Integral Muting (German)
08/06/18
Datasheet
582K
SGS Safety Grid System Daily Checkout Procedure (Muting Models) (German)
SGS Sicherheitsgittersystem
08/06/18
Checkout Procedure
108K
SGS Safety Grid System Semi-Annual Checkout Procedure (Muting Models) (German)
SGS Sicherheitsgittersystem
08/06/18
Checkout Procedure
78K
Date
Type
Size
SGS Safety Grid System (Emitter/Receiver with Integral Muting) -- Instruction Manual (Italian)
02/14/20
Product Manual
13.3MB
SGS Safety Grid System (Active/Passive with Integral Muting) - Instruction Manual (Italian)
02/14/20
Product Manual
14.5MB
SGS Safety Grid System (ActivePassive) -- Instruction Manual (Italian)
02/14/20
Product Manual
5.4MB
SGS Safety Grid System (EmitterReceiver) -- Instruction Manual (Italian)
02/14/20
Product Manual
4.6MB
SGS Safety Grid System Daily Checkout Procedure (Non-Muting Models) (Italian)
01/04/19
Checkout Procedure
114K
SGS Safety Grid System Semi-Annual Checkout Procedure (Non-Muting Models) (Italian)
01/04/19
Checkout Procedure
82K
SGSA-LXT Muting Arm Sensor Kits for SGS Safety Grid Systems with Integral Muting (Italian)
08/06/18
Datasheet
581K
SGS Safety Grid System Daily Checkout Procedure (Muting Models) (Italian)
08/06/18
Checkout Procedure
115K
SGS Safety Grid System Semi-Annual Checkout Procedure (Muting Models) (Italian)
08/06/18
Checkout Procedure
83K

Marketing Literature

Date
Type
Size
Safety Solutions Catalog
Safety Solutions Catalog
2 Dec 2024
Product Brochure
11.5MB
SGS Safety Grids Sell Sheet
7 Dec 2021
Product Brochure
1.8MB
Date
Type
Size
CN_Safety Solutions Catalog
安全解决方案
06/09/23
Product Brochure
14.8MB
SGS Safety Grids Sell Sheet
SGS 安全光栅系统
10/25/18
Product Brochure
2.4MB
Area and Gate Guarding on Automotive Assembly Line
Area and Gate Guarding on Automotive Assembly Line

Integral hinge will stop conveyor once the gate is opened and the grid is muted when gate is opened.

Perimeter Guarding on a Tube Bending Machine
Perimeter Guarding on a Tube Bending Machine

Widely spaced SGS safety grid platform light screen economically protects the perimeter of a work area. The grid is far enough from the hazard that motion has time to stop if a person or object passes through the grid.

Guarding Conveyor Entry on Palletizer Machines
Guarding Conveyor Entry on Palletizer Machines

Safeguarding palletizer machines present many challenges to keep personnel safe and maintain efficient production. The new SGS Safety Grid with muting arm bar kit protects the dangerous robotic machinery while allowing boxes to pass through the Grids without stopping production. The muting arms can recognize if anything other than a box passes through the Grids and will trigger a machine stop on the palletizer.

SGS - Safety Grid System [Video]
SGS - Safety Grid System

SGS Safety Grid Systems are cost-effective multiple beam safety light devices for access and long-range perimeter guarding applications.

Product Selection

Loading...

Narrow Results

clear all filters

Defined Area Height (mm)

  • (6)
  • (6)
  • (6)
  • (6)

Operating Distance (m)

  • (8)
  • (3)
  • (9)
  • (4)

Integral Muting

  • (12)

System Type

  • (12)
  • (4)
  • (8)

Resolution (mm)

  • (6)
  • (6)
  • (6)
  • (6)
View All View Less
selected filters
  1. SGSSA4-400Q8

    logo with r symbol

    SGS Safety Grid System, Active Transceiver
    Beams: 4; Resolution: 400 mm; Range: 0.5-8 m
    8-pin M12 Integral QD
    Auto/Manual Start/Restart, EDM
    Mounting Hardware Ordered Separately

  2. SGSSP4-300Q88

    logo with r symbol

    SGS Safety Grid System, Emitter/Receiver Pair
    Beams: 4; Resolution: 300 mm; Range: 0.5 to 30 m
    8-pin M12 Integral QD
    Scan Codes, Auto/Manual Start/Restart, EDM
    Mounting Hardware Ordered Separately

  3. SGSSP4-400Q88

    logo with r symbol

    SGS Safety Grid System, Emitter/Receiver Pair
    Beams: 4; Resolution: 400 mm; Range: 0.5 to 30 m
    8-pin M12 Integral QD
    Scan Codes, Auto/Manual Start/Restart, EDM
    Mounting Hardware Ordered Separately

  4. SGSXP2-500Q88

    logo with r symbol

    SGS Safety Grid System, Emitter/Receiver Pair
    Beams: 2; Resolution: 500 mm; Range: 6 to 60 m
    8-pin M12 Integral QD
    Scan Codes, Auto/Manual Start/Restart, EDM
    Mounting Hardware Ordered Separately

  5. SGSXP3-400Q88

    logo with r symbol

    SGS Safety Grid System, Emitter/Receiver Pair
    Beams: 3; Resolution: 400 mm; Range: 6 to 60 m
    8-pin M12 Integral QD
    Scan Codes, Auto/Manual Start/Restart, EDM
    Mounting Hardware Ordered Separately

  6. SGSXP4-400Q88

    logo with r symbol

    SGS Safety Grid System, Emitter/Receiver Pair
    Beams: 4; Resolution: 400 mm; Range: 6 to 60 m
    8-pin M12 Integral QD
    Scan Codes, Auto/Manual Start/Restart, EDM
    Mounting Hardware Ordered Separately

  7. SGSB2-500

    logo with r symbol

    Safety Grid, Passive Mirror Assembly
    Beams: 2; Resolution: 500 mm; Range: 0.5-8 m
    Mounting Hardware Ordered Separately

  8. SGSB3-400

    logo with r symbol

    Safety Grid, Passive Mirror Assembly
    Beams: 3; Resolution: 400 mm; Range: 0.5-8 m
    Mounting Hardware Ordered Separately

  9. SGSB4-300

    logo with r symbol

    Safety Grid, Passive Mirror Assembly
    Beams: 4; Resolution: 300 mm; Range: 0.5 to 6.5 m
    Mounting Hardware Ordered Separately

  10. SGSB4-400

    logo with r symbol

    Safety Grid, Passive Mirror Assembly
    Beams: 4; Resolution: 400 mm; Range: 0.5-8 m
    Mounting Hardware Ordered Separately

  11. SGSMA2-500Q12

    logo with r symbol

    SGS Safety Grid System, Active Transceiver
    Beams: 2; Resolution: 500 mm; Range: 0.5-8 m
    12-pin M12 QD; 5-pin M12 QD
    Auto/Manual Start/Restart, EDM, Integral Muting
    Mounting Hardware Ordered Separately

  12. SGSMA3-400Q12

    logo with r symbol

    SGS Safety Grid System, Active Transceiver
    Beams: 3; Resolution: 400 mm; Range: 0.5-8 m
    12-pin M12 QD; 5-pin M12 QD
    Auto/Manual Start/Restart, EDM, Integral Muting
    Mounting Hardware Ordered Separately

  13. SGSMA4-300Q12

    logo with r symbol

    SGS Safety Grid System, Active Transceiver
    Beams: 4; Resolution: 300 mm; Range: 0.5 to 6.5 m
    12-pin M12 QD; 5-pin M12 QD
    Auto/Manual Start/Restart, EDM, Integral Muting
    Mounting Hardware Ordered Separately

  14. SGSMA4-400Q12

    logo with r symbol

    SGS Safety Grid System, Active Transceiver
    Beams: 4; Resolution: 400 mm; Range: 0.5-8 m
    12-pin M12 QD; 5-pin M12 QD
    Auto/Manual Start/Restart, EDM, Integral Muting
    Mounting Hardware Ordered Separately

  15. SGSMP2-500Q128

    logo with r symbol

    SGS Safety Grid System, Emitter/Receiver Pair
    Beams: 2; Resolution: 500 mm; Range: 0.5 to 30 m
    12-pin M12 QD (R), 8-pin (E); 5-pin M12 QD
    Scan Codes, Auto/Manual Start/Restart, EDM, Integral Muting
    Mounting Hardware Ordered Separately

  16. SGSMP3-400Q128

    logo with r symbol

    SGS Safety Grid System, Emitter/Receiver Pair
    Beams: 3; Resolution: 400 mm; Range: 0.5 to 30 m
    12-pin M12 QD (R), 8-pin (E); 5-pin M12 QD
    Scan Codes, Auto/Manual Start/Restart, EDM, Integral Muting
    Mounting Hardware Ordered Separately

  17. SGSMP4-300Q128

    logo with r symbol

    SGS Safety Grid System, Emitter/Receiver Pair
    Beams: 4; Resolution: 300 mm; Range: 0.5 to 30 m
    12-pin M12 QD (R), 8-pin (E); 5-pin M12 QD
    Scan Codes, Auto/Manual Start/Restart, EDM, Integral Muting
    Mounting Hardware Ordered Separately

  18. SGSMP4-400Q128

    logo with r symbol

    SGS Safety Grid System, Emitter/Receiver Pair
    Beams: 4; Resolution: 400 mm; Range: 0.5 to 30 m
    12-pin M12 QD (R), 8-pin (E); 5-pin M12 QD
    Scan Codes, Auto/Manual Start/Restart, EDM, Integral Muting
    Mounting Hardware Ordered Separately

  19. SGSSA2-500Q8

    logo with r symbol

    SGS Safety Grid System, Active Transceiver
    Beams: 2; Resolution: 500 mm; Range: 0.5-8 m
    8-pin M12 Integral QD
    Auto/Manual Start/Restart, EDM
    Mounting Hardware Ordered Separately

  20. SGSSA3-400Q8

    logo with r symbol

    SGS Safety Grid System, Active Transceiver
    Beams: 3; Resolution: 400 mm; Range: 0.5-8 m
    8-pin M12 Integral QD
    Auto/Manual Start/Restart, EDM
    Mounting Hardware Ordered Separately

  21. SGSSA4-300Q8

    logo with r symbol

    SGS Safety Grid System, Active Transceiver
    Beams: 4; Resolution: 300 mm; Range: 0.5 to 6.5 m
    8-pin M12 Integral QD
    Auto/Manual Start/Restart, EDM
    Mounting Hardware Ordered Separately

  22. SGSSP2-500Q88

    logo with r symbol

    SGS Safety Grid System, Emitter/Receiver Pair
    Beams: 2; Resolution: 500 mm; Range: 0.5 to 30 m
    8-pin M12 Integral QD
    Scan Codes, Auto/Manual Start/Restart, EDM
    Mounting Hardware Ordered Separately

  23. SGSSP3-400Q88

    logo with r symbol

    SGS Safety Grid System, Emitter/Receiver Pair
    Beams: 3; Resolution: 400 mm; Range: 0.5 to 30 m
    8-pin M12 Integral QD
    Scan Codes, Auto/Manual Start/Restart, EDM
    Mounting Hardware Ordered Separately

  24. SGSXP4-300Q88

    logo with r symbol

    SGS Safety Grid System, Emitter/Receiver Pair
    Beams: 4; Resolution: 300 mm; Range: 6 to 60 m
    8-pin M12 Integral QD
    Scan Codes, Auto/Manual Start/Restart, EDM
    Mounting Hardware Ordered Separately

Add to My Library
Added