Especificaciones
- IP Rating
- IP20
- Power
- DC
- Device Type
- Safety Controller
- In-Series Diagnostics
- Yes
- Safety Module Type
- Base Controller
- Expandable
- No
- LCD Display
- No
- Dimension (H x W x D in mm)
- 115 x 45 x 100
- Relative Humidity
- 90% @ 50° C
- Max Operating Temperature ( °C)
- 55
- Input Operation
- Simultaneous or Concurrent
- Number of Safe Inputs
- 10
- Input Configuration
- Configurable
- Number of Convertible Inputs
- 4
- Safety Input - Dual Channel (Dry Contact)
- 5-50 mA @ 24 V dc
- Safety Input - Dual Channel (Solid-State)
- 50 mA @ 15 - 30 V dc
- Safety Input - Reset
- 5-50 mA @ 24 V dc
- Independently Controlled Safe Outputs
- 2
- Output Configuration
- 2 sets of 3 NO
- Non Safe Output Configuration
- Up to 4 PNP
- Non Safe Output Rating
- 80 mA @ 24 V dc (individual) maximum; overcurrent protected
- Safe Output Rating
- Relay - 6 A
- Splittable Safe Output
- No
- Mechanical Life (Operations in Millions)
- 20
- Power Consumption
- 0.24 A (no load, relays on), 0.53 A (full load, relays on)
- Response Time (ms)
- See Software Configuration Summary
- Supply Voltage
- 24 V dc +/- 20%
- Terminal Type
- Spring Clamp
- Removable Terminals
- No
- Vibration
- 9-150 Hz at 1g occasional/0.5g continuous
- Electrical Life (Cycles @ VA)
- 50,000 @ full resistive load
- PL Rating
- e
- Safety Category Rating
- 4
- SIL Rating
- 3
- SISTEMA
- PFHd = 5.0 x 10-10
- THC Rating
- IIIC
- Safety Input - Single Channel
- 5-50 mA @ 24 V dc
- Input Resistance
- 150 Ω max. per lead
- E-Stops/Rope Pulls
- Yes
- Safety Mat
- Yes
- Motor Speed
- No
- Two-Hand Controls
- Yes
- Muting
- Yes
- Gate Switch (NC/NC) Input
- Yes
- Gate Switch (NC/NO) Input
- Yes
- Gate Switch (OSSD) Input
- Yes
- Light Curtains/Scanner with EDM Input
- Yes
- Light Curtains/Scanner without EDM Input
- Yes
- EtherNet/IP
- Yes
- Modbus/TCP
- Yes
- PCCC
- Yes
- PROFINET
- Yes
- Recovery Time
- 250 (typical), 400 (max)
- EPLAN Status
- Published
- EPLAN Original Sent Date
- 06/15/2022
Descargas
Archivos CAD
Documentación técnica
Date
Type
Size
Certificaciones
Date
Type
Size
Archivos con Datos del Producto
Date
Type
Size
PLC Support Files
Date
Type
Size
Software
Date
Type
Size
EPLAN
Date
Type
Size
SC10-2roe
Detalle del Producto: SC10 Series Safety Controller / Relay Hybrid