XS16SI
Certifications
Compatible Amplifiers
Where applicable, maximum range for opposed mode fibers is also dependent on fiber length.
Accessories to Complete Your System
Add all or individual items to your cart. More options available below.
Specifications
- IP Rating
- IP20
- Device Type
- Safety Controller
- In-Series Diagnostics
- No
- Safety Module Type
- Input Module
- Expandable
- Yes
- LCD Display
- No
- Dimension (H x W x D in mm)
- 110 x 22.5 x 129
- Relative Humidity
- 90% @ 50° C
- Max Operating Temperature ( °C)
- 55
- Input Operation
- Simultaneous or Concurrent
- Number of Safe Inputs
- 16
- Input Configuration
- Configurable
- Number of Convertible Inputs
- 4
- Safety Input - Dual Channel (Dry Contact)
- 5-50 mA @ 24 V dc
- Safety Input - Dual Channel (Solid-State)
- 50 mA @ 15 - 30 V dc
- Safety Input - Reset
- 5-50 mA @ 24 V dc
- Non Safe Output Configuration
- Up to 4 PNP
- Non Safe Output Rating
- 80 mA @ 24 V dc (individual) maximum; overcurrent protected
- Safe Output Rating
- N/A
- Splittable Safe Output
- No
- Power Consumption
- 0.09 A (no load); 0.41 A (full load)
- Response Time (ms)
- See Software Configuration Summary
- Terminal Type
- Screw
- Removable Terminals
- Yes
- Vibration
- 9-150 Hz at 1g occasional/0.5g continuous
- PL Rating
- e
- Safety Category Rating
- 4
- SIL Rating
- 3
- SISTEMA
- PFHd = 4 x 10-10
- THC Rating
- IIIC
- Safety Input - Single Channel
- 5-50 mA @ 24 V dc
- Input Resistance
- 150 Ω max. per lead
- E-Stops/Rope Pulls
- Yes
- Safety Mat
- Yes
- Motor Speed
- No
- Two-Hand Controls
- Yes
- Muting
- Yes
- Gate Switch (NC/NC) Input
- Yes
- Gate Switch (NC/NO) Input
- Yes
- Gate Switch (OSSD) Input
- Yes
- Light Curtains/Scanner with EDM Input
- Yes
- Light Curtains/Scanner without EDM Input
- Yes
- Recovery Time
- 250 (typical), 400 (max)