• Back

  • Safety Grid System

    SGS Series

    SGS Safety Grid Systems are cost-effective multiple beam safety light devices for access and long-range perimeter guarding applications. They are available in Emitter/Receiver models capable of safeguarding over very long distances and in easy-to-deploy Active/Passive models that offer additional cost savings.

    • Models available with integral muting for entry/exit conveyors or palletizing cells
    • Heavy-duty aluminum housing for tough environments
    • Easy alignment and installation with on-board alignment lamp and indicators
    • Protective defined area heights of 500, 800, 900, or 1200 mm available
    • Up to 60 meter range available for perimeter guarding applications
    • Muting arm kits available to simplify end-of-line packaging applications
    OPTIMIZE CONTROL SYSTEM PERFORMANCE
    Remote I/O

    Technical Literature

    Date
    Type
    Size
    SGS Safety Grid System (Emitter-Receiver Models) Instruction Manual
    5 Oct 2023
    Product Manual
    7.7MB
    SGS Safety Grid System (Active-Passive Models) Instruction Manual
    5 Oct 2023
    Product Manual
    8.1MB
    SGS Safety Grid System (Emitter-Receiver Models with Integral Muting) Instruction Manual
    5 Oct 2023
    Product Manual
    7.5MB
    SGS Safety Grid System (Active-Passive Models with Integral Muting) Instruction Manual
    5 Oct 2023
    Product Manual
    7.9MB
    SGSA-LXT Muting Arm Sensor Kits for SGS Safety Grid Systems with Integral Muting
    2 Aug 2021
    Datasheet
    633K
    SGS Safety Grid System Semi-Annual Checkout Procedure (Muting Models)
    16 Jan 2018
    Checkout Procedure
    92K
    SGS Safety Grid System Daily Checkout Procedure (Muting Models)
    16 Jan 2018
    Checkout Procedure
    121K
    SGS Safety Grid System Daily Checkout Procedure (Non-Muting Models)
    16 Jan 2018
    Checkout Procedure
    121K
    SGS Safety Grid System Semi-Annual Checkout Procedure (Non-Muting Models)
    16 Jan 2018
    Checkout Procedure
    88K
    SGSA-MCB Safety Grid System Connection Box
    22 Sep 2017
    Datasheet
    460K
    Date
    Type
    Size
    SGS Safety Grid System (Emitter/Receiver with Integral Muting) -- Instruction Manual (French)
    12/19/19
    Product Manual
    13.6MB
    SGS Safety Grid System (Emitter/Receiver) -- Instruction Manual (French)
    12/19/19
    Product Manual
    4.6MB
    SGS Safety Grid System (Active/Passive with Integral Muting) - Instruction Manual (French)
    12/19/19
    Product Manual
    14.5MB
    SGS Safety Grid System (ActivePassive) -- Instruction Manual (French)
    12/19/19
    Product Manual
    5.4MB
    SGS Safety Grid System Semi-Annual Checkout Procedure (Non-Muting Models) (French)
    01/04/19
    Checkout Procedure
    82K
    SGS Safety Grid System Daily Checkout Procedure (Non-Muting Models) (French)
    01/04/19
    Checkout Procedure
    115K
    SGSA-LXT Muting Arm Sensor Kits for SGS Safety Grid Systems with Integral Muting (French)
    08/06/18
    Datasheet
    583K
    SGS Safety Grid System Daily Checkout Procedure (Muting Models) (French)
    08/06/18
    Checkout Procedure
    115K
    SGS Safety Grid System Semi-Annual Checkout Procedure (Muting Models) (French)
    08/06/18
    Checkout Procedure
    86K
    Date
    Type
    Size
    SGS Safety Grid System (Emitter/Receiver with Integral Muting) -- Instruction Manual (German)
    02/14/20
    Product Manual
    13.3MB
    SGS Safety Grid System (Active/Passive with Integral Muting) - Instruction Manual (German)
    02/14/20
    Product Manual
    14.5MB
    SGS Safety Grid System (ActivePassive) -- Instruction Manual (German)
    02/14/20
    Product Manual
    5.4MB
    SGS Safety Grid System (EmitterReceiver) -- Instruction Manual (German)
    02/14/20
    Product Manual
    4.6MB
    SGS Safety Grid System Daily Checkout Procedure (Non-Muting Models) (German)
    01/04/19
    Checkout Procedure
    108K
    SGS Safety Grid System Semi-Annual Checkout Procedure (Non-Muting Models) (German)
    01/04/19
    Checkout Procedure
    75K
    SGSA-LXT Muting Arm Sensor Kits for SGS Safety Grid Systems with Integral Muting (German)
    08/06/18
    Datasheet
    582K
    SGS Safety Grid System Daily Checkout Procedure (Muting Models) (German)
    SGS Sicherheitsgittersystem
    08/06/18
    Checkout Procedure
    108K
    SGS Safety Grid System Semi-Annual Checkout Procedure (Muting Models) (German)
    SGS Sicherheitsgittersystem
    08/06/18
    Checkout Procedure
    78K
    Date
    Type
    Size
    SGS Safety Grid System (Emitter/Receiver with Integral Muting) -- Instruction Manual (Italian)
    02/14/20
    Product Manual
    13.3MB
    SGS Safety Grid System (Active/Passive with Integral Muting) - Instruction Manual (Italian)
    02/14/20
    Product Manual
    14.5MB
    SGS Safety Grid System (ActivePassive) -- Instruction Manual (Italian)
    02/14/20
    Product Manual
    5.4MB
    SGS Safety Grid System (EmitterReceiver) -- Instruction Manual (Italian)
    02/14/20
    Product Manual
    4.6MB
    SGS Safety Grid System Daily Checkout Procedure (Non-Muting Models) (Italian)
    01/04/19
    Checkout Procedure
    114K
    SGS Safety Grid System Semi-Annual Checkout Procedure (Non-Muting Models) (Italian)
    01/04/19
    Checkout Procedure
    82K
    SGSA-LXT Muting Arm Sensor Kits for SGS Safety Grid Systems with Integral Muting (Italian)
    08/06/18
    Datasheet
    581K
    SGS Safety Grid System Daily Checkout Procedure (Muting Models) (Italian)
    08/06/18
    Checkout Procedure
    115K
    SGS Safety Grid System Semi-Annual Checkout Procedure (Muting Models) (Italian)
    08/06/18
    Checkout Procedure
    83K

    Marketing Literature

    Date
    Type
    Size
    Safety Solutions Catalog
    Safety Solutions Catalog
    13 May 2024
    Product Brochure
    11.5MB
    SGS Safety Grids Sell Sheet
    7 Dec 2021
    Product Brochure
    1.8MB
    Date
    Type
    Size
    CN_Safety Solutions Catalog
    安全解决方案
    06/09/23
    Product Brochure
    14.8MB
    SGS Safety Grids Sell Sheet
    SGS 安全光栅系统
    10/25/18
    Product Brochure
    2.4MB
    Area and Gate Guarding on Automotive Assembly Line
    Area and Gate Guarding on Automotive Assembly Line

    Integral hinge will stop conveyor once the gate is opened and the grid is muted when gate is opened.

    Perimeter Guarding on a Tube Bending Machine
    Perimeter Guarding on a Tube Bending Machine

    Widely spaced SGS safety grid platform light screen economically protects the perimeter of a work area. The grid is far enough from the hazard that motion has time to stop if a person or object passes through the grid.

    Guarding Conveyor Entry on Palletizer Machines
    Guarding Conveyor Entry on Palletizer Machines

    Safeguarding palletizer machines present many challenges to keep personnel safe and maintain efficient production. The new SGS Safety Grid with muting arm bar kit protects the dangerous robotic machinery while allowing boxes to pass through the Grids without stopping production. The muting arms can recognize if anything other than a box passes through the Grids and will trigger a machine stop on the palletizer.

    SGS - Safety Grid System [Video]
    SGS - Safety Grid System

    SGS Safety Grid Systems are cost-effective multiple beam safety light devices for access and long-range perimeter guarding applications.

    Product Selection

    Loading...

    Narrow Results

    clear all filters

    Defined Area Height (mm)

    • (6)
    • (6)
    • (6)
    • (6)

    Operating Distance (m)

    • (8)
    • (3)
    • (9)
    • (4)

    Integral Muting

    • (12)

    System Type

    • (12)
    • (4)
    • (8)

    Resolution (mm)

    • (6)
    • (6)
    • (6)
    • (6)
    View All View Less
    selected filters
    1. SGSXP3-400Q88

      logo with r symbol

      SGS Safety Grid System, Emitter/Receiver Pair
      Beams: 3; Resolution: 400 mm; Range: 6 to 60 m
      8-pin M12 Integral QD
      Scan Codes, Auto/Manual Start/Restart, EDM
      Mounting Hardware Ordered Separately

    2. SGSSP4-400Q88

      logo with r symbol

      SGS Safety Grid System, Emitter/Receiver Pair
      Beams: 4; Resolution: 400 mm; Range: 0.5 to 30 m
      8-pin M12 Integral QD
      Scan Codes, Auto/Manual Start/Restart, EDM
      Mounting Hardware Ordered Separately

    3. SGSSA4-400Q8

      logo with r symbol

      SGS Safety Grid System, Active Transceiver
      Beams: 4; Resolution: 400 mm; Range: 0.5-8 m
      8-pin M12 Integral QD
      Auto/Manual Start/Restart, EDM
      Mounting Hardware Ordered Separately

    4. SGSSP4-300Q88

      logo with r symbol

      SGS Safety Grid System, Emitter/Receiver Pair
      Beams: 4; Resolution: 300 mm; Range: 0.5 to 30 m
      8-pin M12 Integral QD
      Scan Codes, Auto/Manual Start/Restart, EDM
      Mounting Hardware Ordered Separately

    5. SGSB4-400

      logo with r symbol

      Safety Grid, Passive Mirror Assembly
      Beams: 4; Resolution: 400 mm; Range: 0.5-8 m
      Mounting Hardware Ordered Separately

    6. SGSSP3-400Q88

      logo with r symbol

      SGS Safety Grid System, Emitter/Receiver Pair
      Beams: 3; Resolution: 400 mm; Range: 0.5 to 30 m
      8-pin M12 Integral QD
      Scan Codes, Auto/Manual Start/Restart, EDM
      Mounting Hardware Ordered Separately

    7. SGSXP4-300Q88

      logo with r symbol

      SGS Safety Grid System, Emitter/Receiver Pair
      Beams: 4; Resolution: 300 mm; Range: 6 to 60 m
      8-pin M12 Integral QD
      Scan Codes, Auto/Manual Start/Restart, EDM
      Mounting Hardware Ordered Separately

    8. SGSXP4-400Q88

      logo with r symbol

      SGS Safety Grid System, Emitter/Receiver Pair
      Beams: 4; Resolution: 400 mm; Range: 6 to 60 m
      8-pin M12 Integral QD
      Scan Codes, Auto/Manual Start/Restart, EDM
      Mounting Hardware Ordered Separately

    9. SGSB4-300

      logo with r symbol

      Safety Grid, Passive Mirror Assembly
      Beams: 4; Resolution: 300 mm; Range: 0.5 to 6.5 m
      Mounting Hardware Ordered Separately

    10. SGSSA4-300Q8

      logo with r symbol

      SGS Safety Grid System, Active Transceiver
      Beams: 4; Resolution: 300 mm; Range: 0.5 to 6.5 m
      8-pin M12 Integral QD
      Auto/Manual Start/Restart, EDM
      Mounting Hardware Ordered Separately

    11. SGSXP2-500Q88

      logo with r symbol

      SGS Safety Grid System, Emitter/Receiver Pair
      Beams: 2; Resolution: 500 mm; Range: 6 to 60 m
      8-pin M12 Integral QD
      Scan Codes, Auto/Manual Start/Restart, EDM
      Mounting Hardware Ordered Separately

    12. SGSB3-400

      logo with r symbol

      Safety Grid, Passive Mirror Assembly
      Beams: 3; Resolution: 400 mm; Range: 0.5-8 m
      Mounting Hardware Ordered Separately

    13. SGSB2-500

      logo with r symbol

      Safety Grid, Passive Mirror Assembly
      Beams: 2; Resolution: 500 mm; Range: 0.5-8 m
      Mounting Hardware Ordered Separately

    14. SGSSA2-500Q8

      logo with r symbol

      SGS Safety Grid System, Active Transceiver
      Beams: 2; Resolution: 500 mm; Range: 0.5-8 m
      8-pin M12 Integral QD
      Auto/Manual Start/Restart, EDM
      Mounting Hardware Ordered Separately

    15. SGSSP2-500Q88

      logo with r symbol

      SGS Safety Grid System, Emitter/Receiver Pair
      Beams: 2; Resolution: 500 mm; Range: 0.5 to 30 m
      8-pin M12 Integral QD
      Scan Codes, Auto/Manual Start/Restart, EDM
      Mounting Hardware Ordered Separately

    16. SGSMA3-400Q12

      logo with r symbol

      SGS Safety Grid System, Active Transceiver
      Beams: 3; Resolution: 400 mm; Range: 0.5-8 m
      12-pin M12 QD; 5-pin M12 QD
      Auto/Manual Start/Restart, EDM, Integral Muting
      Mounting Hardware Ordered Separately

    17. SGSMA4-300Q12

      logo with r symbol

      SGS Safety Grid System, Active Transceiver
      Beams: 4; Resolution: 300 mm; Range: 0.5 to 6.5 m
      12-pin M12 QD; 5-pin M12 QD
      Auto/Manual Start/Restart, EDM, Integral Muting
      Mounting Hardware Ordered Separately

    18. SGSMA4-400Q12

      logo with r symbol

      SGS Safety Grid System, Active Transceiver
      Beams: 4; Resolution: 400 mm; Range: 0.5-8 m
      12-pin M12 QD; 5-pin M12 QD
      Auto/Manual Start/Restart, EDM, Integral Muting
      Mounting Hardware Ordered Separately

    19. SGSMP4-400Q128

      logo with r symbol

      SGS Safety Grid System, Emitter/Receiver Pair
      Beams: 4; Resolution: 400 mm; Range: 0.5 to 30 m
      12-pin M12 QD (R), 8-pin (E); 5-pin M12 QD
      Scan Codes, Auto/Manual Start/Restart, EDM, Integral Muting
      Mounting Hardware Ordered Separately

    20. SGSSA3-400Q8

      logo with r symbol

      SGS Safety Grid System, Active Transceiver
      Beams: 3; Resolution: 400 mm; Range: 0.5-8 m
      8-pin M12 Integral QD
      Auto/Manual Start/Restart, EDM
      Mounting Hardware Ordered Separately

    21. SGSMA2-500Q12

      logo with r symbol

      SGS Safety Grid System, Active Transceiver
      Beams: 2; Resolution: 500 mm; Range: 0.5-8 m
      12-pin M12 QD; 5-pin M12 QD
      Auto/Manual Start/Restart, EDM, Integral Muting
      Mounting Hardware Ordered Separately

    22. SGSMP2-500Q128

      logo with r symbol

      SGS Safety Grid System, Emitter/Receiver Pair
      Beams: 2; Resolution: 500 mm; Range: 0.5 to 30 m
      12-pin M12 QD (R), 8-pin (E); 5-pin M12 QD
      Scan Codes, Auto/Manual Start/Restart, EDM, Integral Muting
      Mounting Hardware Ordered Separately

    23. SGSMP3-400Q128

      logo with r symbol

      SGS Safety Grid System, Emitter/Receiver Pair
      Beams: 3; Resolution: 400 mm; Range: 0.5 to 30 m
      12-pin M12 QD (R), 8-pin (E); 5-pin M12 QD
      Scan Codes, Auto/Manual Start/Restart, EDM, Integral Muting
      Mounting Hardware Ordered Separately

    24. SGSMP4-300Q128

      logo with r symbol

      SGS Safety Grid System, Emitter/Receiver Pair
      Beams: 4; Resolution: 300 mm; Range: 0.5 to 30 m
      12-pin M12 QD (R), 8-pin (E); 5-pin M12 QD
      Scan Codes, Auto/Manual Start/Restart, EDM, Integral Muting
      Mounting Hardware Ordered Separately

    Add to My Library
    Added