SI-RFSL-HP8
Informations sur l'article RFID Safety Switches
Certifications
Amplificateurs compatibles
Dans les cas applicables, la portée maximale des fibres en mode barrière dépend également de la longueur de la fibre.
Spécifications
- IP Rating
- IP69
- Switch Style
- Non-Contact
- Device Type
- RFID - Sensor
- Primary Housing Material
- Thermoplastic
- In-Series Diagnostics
- No
- Actuation
- Standard
- Device Size
- 36 x 26 x 15
- Device Shape
- Rectangular
- Min Op. Temperature (°C)
- -25
- Max Op. Temperature (°C)
- 70
- Relative Humidity
- 93% @ 50 °C
- PL Rating
- PL e
- SIL Rating
- SIL CL 3
- Safety Category
- Cat 4
- SISTEMA
- PFHd of 1 x 10-9
- Actuator (Safety) Contacts
- 2 NC
- Monitor (Locked) Contacts
- N/A
- Output Type
- OSSD
- OSSD Rating
- 24 VDC @ 0.1 A each
- Connection Type
- M12 Pigtail
- Connection
- Pigtail QD
- Feature: Cascade
- Yes
- Feature: Quick Disconnect
- Yes
- H Typical (mm)
- 2
- Operating Voltage
- 24 V dc +25%, -20%
- Rated Operating Current
- 50 mA + output loads
- Sn Typical
- 13
- Sar Maximum (mm)
- 25
- Number of Pins
- 8
- Sao Minimum (mm)
- 10
- Coding Level/Tamper Resistance
- High
- Auxilliary Output
- Yes
- Response Time (ms)
- 100
- Trip Latch Output
- Latch
Téléchargements